Protective Equipment

  • user’s protection is secured by inner positive pressure
  • filtration-ventilation unit supplies sufficient amount of filtered air (120 dm3/min)
  • accumulator guarantees at least 8 hours of operating time
  • quality of filtered air is ensured by appropriate filters, placed outside the suit
  • optimal volume of inner positive pressure is ensured by one-way overpressure valves
  • large view-through
  • special hermetic zip fastener
  • all seams are super-sealed by elastomeric mixture
  • fabric: butyl rubber

Technical parameters

  • weight of the suit approx. 3000 g for size No.1 (without: filtration-ventilation unit, underwear, boots and gloves)
  • weight of boots: 2200 g for size No.45
  • weight of filtration-ventilation unit: 1650 g (incl. 2 pcs of P3 filter and air hose)